COMMAND
MS IE
SYSTEMS AFFECTED
IE 5
PROBLEM
Ed Sparks discovered that if IE 5.0 is installed on a machine
after SP5 has been installed, and SP5 is not re-installed,
subsequent applications of new Hotfixes can cause an error;
CAPI: = the install program could not open the signature file
The hotfix installation then appears to fail. Microsoft have
confirmed this to be an issue with IE 5.0 installer. IE 5.0 setup
is/was deleting ENHSIG.DLL, installed by SP5. It should be noted
that Service Packs should be installed after the installation
of any new software. Had this been done the error would not have
been seen as the SP would have re-installed ENHSIG.DLL. Its also
worthwhile noting that despite the error message, Hotfixes are
actually installed successfully despite the error message.
SOLUTION
Microsoft have indicated that IE 5.0 installer will be modified
to prevent it from removing ENHSIG.DLL.